Home › Codes › SPN 108 › FMI 2
SPN 108 FMI 2
Barometric Pressure — Data erratic, intermittent, or incorrect.
The signal jumps around, drops in and out, or disagrees with other information the controller has.
What the SPN covers: Outside air pressure, used to correct fueling and boost for altitude. More on SPN 108.
What FMI 2 usually points to: Loose or corroded connectors, chafed wiring, a failing sensor, or two redundant sensors that do not agree. More on FMI 2.
Severity
LOW — usually OK to keep running
Usually a minor drivability issue, but get it fixed so boost and fueling stay accurate.
Likely causes
- Faulty barometric sensor (often inside the ECM)
- Wiring fault on external sensors
- ECM internal fault
Checks & fixes (easiest first)
- Compare reading to local barometric pressure
- Inspect wiring on external sensors
- Check for ECM supply voltage codes
FAQ
What does SPN 108 FMI 2 mean?
Barometric Pressure — data erratic, intermittent, or incorrect. The signal jumps around, drops in and out, or disagrees with other information the controller has.
Is SPN 108 FMI 2 serious?
Usually a minor drivability issue, but get it fixed so boost and fueling stay accurate.
What should I check first for SPN 108 FMI 2?
Compare reading to local barometric pressure; Inspect wiring on external sensors; Check for ECM supply voltage codes.