Home › Codes › SPN 3361 › FMI 5
SPN 3361 FMI 5
Aftertreatment 1 DEF Dosing Unit — Current below normal or open circuit.
Less current is flowing in an output or sensor circuit than expected, which usually means the circuit is open.
What the SPN covers: The DEF doser (injector) that sprays diesel exhaust fluid into the exhaust ahead of the SCR catalyst. More on SPN 3361.
What FMI 5 usually points to: Broken wire, unplugged connector, burned-out coil or solenoid, or a backed-out terminal. More on FMI 5.
Severity
HIGH — limit use, diagnose now
A doser that is stuck, clogged or not firing means NOx is not being reduced, and inducement derates will follow. Repair soon.
Likely causes
- Wiring or connector fault in this circuit (most common for electrical FMIs)
- White urea crystals blocking the doser tip or mixer
- Doser coil open or shorted
- DEF wicked into the doser connector or harness
- Doser stuck open and dribbling after shutdown
Checks & fixes (easiest first)
- Inspect the connector and harness for this circuit: corrosion, water, chafing, backed-out pins
- Check the reference voltage, ground and signal at the component per OEM pin-out
- Pull the doser and inspect the tip and mixer pipe for crystal buildup
- Run the OEM dosing quantity (cup) test and compare with spec
- Measure coil resistance and inspect the connector for DEF intrusion
- Soak light deposits off in warm water; replace the doser if spray or volume stays wrong
FAQ
What does SPN 3361 FMI 5 mean?
Aftertreatment 1 DEF Dosing Unit — current below normal or open circuit. Less current is flowing in an output or sensor circuit than expected, which usually means the circuit is open.
Is SPN 3361 FMI 5 serious?
A doser that is stuck, clogged or not firing means NOx is not being reduced, and inducement derates will follow. Repair soon.
What should I check first for SPN 3361 FMI 5?
Inspect the connector and harness for this circuit: corrosion, water, chafing, backed-out pins; Check the reference voltage, ground and signal at the component per OEM pin-out; Pull the doser and inspect the tip and mixer pipe for crystal buildup.