Home › Codes › SPN 629 › FMI 2
SPN 629 FMI 2
Controller #1 — Data erratic, intermittent, or incorrect.
The signal jumps around, drops in and out, or disagrees with other information the controller has.
What the SPN covers: The engine controller itself has detected an internal problem. More on SPN 629.
What FMI 2 usually points to: Loose or corroded connectors, chafed wiring, a failing sensor, or two redundant sensors that do not agree. More on FMI 2.
Severity
HIGH — limit use, diagnose now
Can range from minor to no-start. Check power and grounds before blaming the ECM.
Likely causes
- Internal ECM fault
- Corrupted or interrupted programming
- Poor power or ground supply
- Water intrusion
Checks & fixes (easiest first)
- Check ECM power and ground
- Check for software updates or a failed reflash
- Inspect connectors for water
FAQ
What does SPN 629 FMI 2 mean?
Controller #1 — data erratic, intermittent, or incorrect. The signal jumps around, drops in and out, or disagrees with other information the controller has.
Is SPN 629 FMI 2 serious?
Can range from minor to no-start. Check power and grounds before blaming the ECM.
What should I check first for SPN 629 FMI 2?
Check ECM power and ground; Check for software updates or a failed reflash; Inspect connectors for water.